Rki-instruments M2 Rig Monitor Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Rki-instruments M2 Rig Monitor. RKI Instruments M2 Rig Monitor User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Operator’s Manual

RKI Instruments, Inc.www.rkiinstruments.comM2 Rig MonitorOperator’s Manual Part Number: 71-0234RKRevision: DReleased: 9/30/14

Page 2

5 M2 Rig Monitor Operator’s ManualThe H2S detector is installed in the junction box’s bottom conduit hub and is factory wired to the M2 through the

Page 3 - Product Warranty

M2 Rig Monitor Operator’s Manual 6Internal DescriptionThis section describes the internal components of the M2 Rig Monitor. The internal components o

Page 4 - Table of Contents

7 M2 Rig Monitor Operator’s Manualsignal may be used by a recording device, gas monitor controller, or programmable controller. The Modbus output m

Page 5

M2 Rig Monitor Operator’s Manual 8Relay Terminal StripsThe right column of terminal strips consists of, from top to bottom, the fail, alarm 1, and al

Page 6 - Chapter 1: Introduction

9 M2 Rig Monitor Operator’s Manualcalibration. They are actuated by bringing the magnetic wand close enough to them to actuate them. Although the m

Page 7 - Specifications

M2 Rig Monitor Operator’s Manual 10Chapter 3: Installation & StartupOverviewThis chapter describes procedures to mount the M2 Rig Monitor in the

Page 8 - Chapter 2: Description

11 M2 Rig Monitor Operator’s Manual• Are the display screen and status lights on the Rig Monitor visible?2. At the monitoring site, use #10 screws

Page 9 - Magnetic Wand

M2 Rig Monitor Operator’s Manual 12Wiring the M2 Rig MonitorWARNING: Always verify that the power source is OFF before making any wiring connections.

Page 10 - 12 VDC Battery Cable

13 M2 Rig Monitor Operator’s ManualFigure 9: Rig Monitor Field WiringConnecting DC PowerPerform the following functions to connect the Rig Monitor

Page 11 - Internal Description

M2 Rig Monitor Operator’s Manual 147. All of the conduit hubs are used in the Rig Monitor so you will need to uninstall the power cable from the bott

Page 12 - Terminal Strip

M2 Rig Monitor Operator’s ManualWARNINGRead and understand this instruction manual before operating instrument. Improper use of the gas monitor co

Page 13 - Control PCB

15 M2 Rig Monitor Operator’s Manual10. Connect the leads from the recording device to the 4-20 mA out terminal strip as shown in Figure 9. When con

Page 14

M2 Rig Monitor Operator’s Manual 16actuate. Touching the glass and removing the wand is the same as pressing and releasing a button. Touching the gla

Page 15 - Mounting the M2 Rig Monitor

17 M2 Rig Monitor Operator’s ManualChapter 4: OperationOverviewThis chapter describes the M2 Rig Monitor in normal operation. This chapter also des

Page 16 - 14.87 Max

M2 Rig Monitor Operator’s Manual 184 - 20 mA Signal Output OperationThe output at the S terminal of the power/signal terminal strip is a 4 - 20 mA si

Page 17 - Wiring the M2 Rig Monitor

19 M2 Rig Monitor Operator’s ManualNOTE: You can select normally energized (N. EN) or normally de-energized (N. DE-EN) alarm 1 and alarm 2 relay se

Page 18 - Connecting External Alarms

M2 Rig Monitor Operator’s Manual 20Alarm 2 ConditionAlarm 2 Condition IndicationsWhen the gas reading reaches the alarm 2 setpoint, the Rig Monitor s

Page 19 - Connecting Recorders

21 M2 Rig Monitor Operator’s ManualLow Power ConditionThe 12 VDC battery that is recommended for operation of the Rig Monitor is typically dead bef

Page 20 - Start Up

M2 Rig Monitor Operator’s Manual 22Chapter 5: Configuration ModeOverviewThis chapter describes how to view and change M2 Rig Monitor parameters using

Page 21

23 M2 Rig Monitor Operator’s ManualTable 4: Configuration ParametersParameter(Factory Set Value)DescriptionALARM-1 (10 ppm)The gas reading at which

Page 22 - 24.2V

M2 Rig Monitor Operator’s Manual 244. When you have scrolled through all the adjustable parameters, SAVE IT? YES/NO appears on the display.5. If you

Page 23 - Alarm Indications

M2 Rig Monitor Operator’s ManualProduct WarrantyRKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in materials, w

Page 24 - Alarm 1 Condition

25 M2 Rig Monitor Operator’s ManualChapter 6: MaintenanceOverviewThis chapter describes procedures for performing preventive maintenance, troublesh

Page 25 - Fail Condition

M2 Rig Monitor Operator’s Manual 26sample tubing from the calibration cup/splash guard hose barb.10. When the Rig Monitor display reading falls below

Page 26 - Low Power Condition

27 M2 Rig Monitor Operator’s ManualStrobe/Horn Not Working• The strobe/horn does not activate when an alarm 1 condition occurs.• The strobe/horn is

Page 27 - Chapter 5: Configuration Mode

M2 Rig Monitor Operator’s Manual 28Calibration FrequencyAlthough there is no particular calibration frequency that is correct for all applications, a

Page 28 - Description

29 M2 Rig Monitor Operator’s ManualPreparing for CalibrationNOTE: The following procedure assumes the use of a calibration kit which includes a cal

Page 29

M2 Rig Monitor Operator’s Manual 308. Press and release the ENTER button. The Rig Monitor will perform a fresh air adjustment and the display will in

Page 30 - Chapter 6: Maintenance

31 M2 Rig Monitor Operator’s ManualAdjusting Strobe/Horn VolumeThe horn volume on the strobe/horn can be adjusted by doing the following:1. Disconn

Page 31 - Troubleshooting

M2 Rig Monitor Operator’s Manual 326. Turn the Audio Select switch so that the selection arrow is pointing to the desired number.7. Place the cover o

Page 32

33 M2 Rig Monitor Operator’s Manual9. Reinstall the junction box cover.10. Connect the battery clamps to the + and - terminals of the 12 VDC batter

Page 33 - Calibration

M2 Rig Monitor Operator’s Manual 34Chapter 7: RS-485 Modbus OutputOverviewThis chapter describes the M2 Rig Monitor’s RS-485 Modbus output and how to

Page 34 - Preparing for Calibration

M2 Rig Monitor Operator’s ManualTable of ContentsChapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35 - Adjusting the Span Setting

35 M2 Rig Monitor Operator’s ManualRecommended Modbus WiringThe recommended Modbus wiring for the Rig Monitor is illustrated in Figure 12 below. In

Page 36 - Adjusting Strobe/Horn Volume

M2 Rig Monitor Operator’s Manual 36Figure 14: Multiple M2 Rig Monitors in a Two Branch ConfigurationUsing the M2 Rig Monitor in a 4-wire Modbus Syste

Page 37 - Rig Monitor

37 M2 Rig Monitor Operator’s Manualfollowing screen appears.2. To exit Modbus Mode, press and release the DOWN/NO button. The M2 Rig Monitor will r

Page 38

M2 Rig Monitor Operator’s Manual 38return to the first adjustable parameter. Go back to step 3 and continue.If you want to save the adjustments made,

Page 39 - Modbus System

39 M2 Rig Monitor Operator’s ManualTable 9: Register 2, Operating State, Alarms & Relays Bit & Field AssignmentsBit(s) Value[15:12] Operati

Page 40 - Termination Jumper

M2 Rig Monitor Operator’s Manual 40Register 3Register 3 is the supply voltage (0.1 volt per count).Registers 4 - 11The 16 bytes in these registers co

Page 41 - Modbus Mode

41 M2 Rig Monitor Operator’s ManualRegister 27Register 27 is the alarm 1 OFF delay.Integer values are in seconds.Register 28Register 28 is the alar

Page 42

M2 Rig Monitor Operator’s Manual 42Register 38Register 38 is the calibration outcome.Upper=Gas OperationLower=Air OperationCalibration Outcome Codes:

Page 43 - Supported Modbus Functions

43 M2 Rig Monitor Operator’s ManualFunction Code 16: Write RegistersThere are 21 registers in Function Code 16 that can be used to write to the Rig

Page 44

M2 Rig Monitor Operator’s Manual 44Parts ListTable 11 lists replacement parts and accessories for the M2 Rig Monitor Transmitter.Table 11: Parts List

Page 45

M2 Rig Monitor Operator’s ManualChapter 6: Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 46

45 M2 Rig Monitor Operator’s ManualAppendix A: Control Button Quick Reference GuideThe M2 Rig Monitor’s control buttons allow access to operational

Page 47

M2 Rig Monitor Operator’s Manual 46Appendix B: Function Code 16 RegistersThe M2 Rig Monitor supports Function Code 16 that allows writing to the Rig

Page 48

47 M2 Rig Monitor Operator’s ManualRegister 9Register 9 is the alarm 2 relay state.0=Normally De-Energized1=Normally EnergizedRegister 10Register 1

Page 49 - Parts List

M2 Rig Monitor Operator’s Manual 48Register 19Register 19 is for clearing change flags. When parameters are changed at the M2 Rig Monitor, a flag is

Page 50

1 M2 Rig Monitor Operator’s ManualChapter 1: IntroductionOverviewThis chapter briefly describes the M2 Rig Monitor. This chapter also describes the

Page 51

M2 Rig Monitor Operator’s Manual 2SpecificationsTable 1 lists specifications for the M2 Rig Monitor.WARNING: When using the M2 Rig Monitor, you must

Page 52

3 M2 Rig Monitor Operator’s ManualChapter 2: DescriptionOverviewThis chapter describes external and internal components of the M2 Rig Monitor.Exter

Page 53 - Register 20

M2 Rig Monitor Operator’s Manual 4Alarm Strobe/HornThe Rig Monitor has a red alarm strobe light/horn installed in the top conduit hub. The Rig Monito

Commentaires sur ces manuels